Kamis, 18 Oktober 2012

CONTROL PANEL DELTA(DIRECT ONLINE/DOL)

NAAAAAAAAH GAN,SEKARANG MARI KITA LIHAT GMBR DI SAMPING.INI ADALAH DIAGRAM PANEL CONTROL YANG BIASANYA MENGGUNAKAN MAGNETIK CONTAKTOR.
NO:NORMALY OPEN(SAAT KEADAN NORMAL/TIDAK ADA PENGARUH APAPUN DIA PASTI DALAM POSISI OPEN ATAU TIDAK NYAMBUNG)
NC:NORMALY CLOSE(ARTINYA SAAT KEADAAN NORMAL/TIDAK ADA PENGARUH APAPUN DIA PASTI DALAM POSISI CLOSE ATAU NYAMBUNG.SEDANGKAN CARA KERJANYA SBB:SAAT ADA ARUS ATAUPUN TEGANGAN MASUK,MAKA DIA AKAN BERHENTI DI NO,KARENA NO MASIH MEMBUKA.UNTUK MEMBERI TEGANGAN PADA COIL MAGNETIK CONTACTOR(COIL MC),MAKA KITA TEKAN/PUSH NO-NYA SEHINGGA ARUS AKAN MENGALIR KE COIL,DAN NO MAGNETIK CONTACTOR AKAN CLOSE/NYAMBUNG.MAKA SAAT KITA MELEPAS TEKANAN KITA DAN NO YANG KITA TEKAN TADI SUDAH TAK NYAMBUNG LAGI,COIL CONTAKTOR MASIH BISA MENDAPAT SUPLAY ARUS MELAUI NO CONTACTOR YANG SDH BERUBAH MENJADI NC.DAN UNTUK MEMATIKAN SUPLAY ARUS DI COIL,KITA CUKUP MENEKAN/PUSH NO,SEMOGA BERMANFAAT

Senin, 15 Oktober 2012

DIAGRAM GENERATOR DAN AVR

ya Allaah,betapa indah ciptaanmu,betapa megah buatanmu.
ya Allaah,jadikan aku insan yang selalu bersyukur.
            Aku sadar,seringkali aku tak menyadari besarnaya nikmat      yang telah kauberikan padaku.
            Aku juga sering tak menyadari betapa besarnya kebahagiaan yang telah kau anugerahkan padaku.
            Maka ampuni dosaku ya Allaah.
            Jadikan aku hambamu yang selalu ingin dekat denganmu.
            Amiiiiiiiiiiiiin...................







                      
                       INI ADALAH DIAGRAM GENERATOR&AVR
DENGAN MELIHAT GAMBAR INI MUNGKIN ANDA (PARA JURAGAN) SEKALIAN AKAN LEBIH MUDAH UNTUK MEMPELAJARINYA

Sabtu, 13 Oktober 2012

CARA MENSETING AVR

NAAAAH...........PARA JURAGAN SEKALIAN,SEKARANG MARI KITA BELAJAR MENYETEL(MENSETING)AVR.DI AVR ADA BEBERAPA TRIMER YANG BISA KITA SETING
1.PERTAMA VOLT TRIMER.JIKA KITA INGIN MENAMBAH NILAI TEGANGAN,KITA          TINGGAL MEMUTAR TRIMER TSB SEARAH JARUM JAM(BEGITU PULA SEBALIKNYA).
2.STABILITY TRIMER.JIKA TEGAGAN YANG DIHASILKAN TIDAK KONSTAN ATAU FLUKTUATIF(SAAT GENSET BELUM BERBEBAN),MAKA TRIMER INI YANG PERLU KITA SETING(PUTAR SEARAH JARUM JAM/CLOCK WISE)
3DROOP TRIMER.SAAT DUA GENSET ATAU LEBIH DALAM KEADAAN SYNCHROON,DAN SAAT GENSET2 ITU MENANGGUNG BEBAN(KW) YANG SAMA,MAKA KITA BERHARAP GENSET2 ITU MENGELUARKAN KVAR YANG SAMA PULA,KARENA JIKA ADA SATU DI ANTARA GENSET2 ITU YANG YANG MEMPUNYAI KVAR TERLALU BESAR,MAKA POWER FAKTORNYA AKAN KECIL,SHG PADA KW YANG SAMA AMPER YANG DIHASILKAN AKAN LEBIH BESAR(KEMUNGKINAN OVER CURRENT AKAN LBH BESAR&GENERATOR AKAN LEBIH CEPAT PANAS)BEGITU JG SEBALIKNYA,JIKA KVARNYA TERLALU KECIL,MAKA POWER FAKTORNYA AKAN TERLALU BESAR(KEMUNGKINAN REVERSE POWER AKAN LBH BESAR).UNTUK MENAMBAH NILAI KVAR KITA PUTAR DROOP TRIMER SEARAH JARUM JAM,BEGITU PULA SEBALIKNYA.
SEMOGA BERMANFAAT............AMIIIIN

Rabu, 10 Oktober 2012

TROUBLE SHOOTING AVR&ALAT2 PADA GENERATOR

SETELAH KITA TAHU CARA KERJA AVR&PMG,SEKARANG MARI KITA BELAJAR TROUBLE SHOOTINGNYA.
            KETIKA ENGGINE SUDAH RUN,TETAPI GENERATOR TIDAK MENGELUARKAN TEGANGAN,MAKA LANGKAH2NYA SBB:
             1.PERIKSA KONEKSI KABEL(TERUTAMA DI AVR)MUNGKIN ADA YG KENDOR ATAU BAHKAN LEPAS.(JIKA LEPAS ATAU KENDOR PERBAIKI)
             2.TES TEGANGAN DI TERMINAL P-1,P-2,P-3(PADA AVR),NILAINYA:150-170VAC.
JIKA NILAINYA KECIL ATAU BAHKAN TIDAK ADA SAMA SEKALI,CHECK PMG STATOR(RESISTANSI:2.3OHM ,LALU CHECK KONDISI VISUAL PMG ROTOR(TIDAK TERBAKAR DAN KONDISI MAGNET MASIH BAGUS),JIKA SEMUA BAGUS MAKA TEGANGAN YANG DA DI TERMINAL P-1,P-2,P-3 TIDAK AKAN KURANG DARI 150VDC.
             3.TES TEGANGAN DI TERMINAL X-1,X-2(13-60VDC),JIKA NILAINYA KURANG DARI 13VDC,SEMENTARA TEGANGAN DI P-1,P-2,P-3 NORMAL,MAKA AVRNYA YG RUSAK DAN HARUS DIGANTI.
              4.JIKA PMG BAIK,AVR JUGA BAIK,STEP BERIKUTNYA CHEK EXSITER STATOR(DNG OHMMETER),BARANGKALI ADA YG PUTUS,LALU CHECK KONDISI VISUAL EXITER ROTOR,BARANGKALI ADA BEKAS GESEKAN ATAU TERBAKAR.
              5.STEP BERIKUTNYA CHEK ROTATING DIODE(PAKAI OHMMETER)DIODA YG MASIH BAIK,KAKI 1 KE KAKI 2 NYAMBUNG TETAPI KALO DI BALIK TIDAK NYAMBUNG.
              6.STEP BERIKUTNYA CHEK VISUAL MAIN GENERATOR STATOR&ROTOR(CARANYA SEPERTI MENGECEK EXITER)
SEKIAN DULU SEMOGA BERMANFAAT.............................................................

Selasa, 09 Oktober 2012

CARA KERJA PMG DAN AVR

CARA KERJA AVR&PMG PADA GENERATOR.SAAT ENGINE BERPUTAR,MAKA PMG STATOR AKAN MENGELUARKAN TEGANGAN AC(150-180V)  2.TEGANGAN DARI PMG AKAN MASUK KE AVR DAN DIUBAH MENJADI TEGANGAN SEARAH/DC(13-60VDC)  3.TEGANGAN ITU LALU DIKIRIM KE EXITER STATOR SBG SUMBER EXSITASI,MAKA PADA EXITER ROTOR AKAN TIMBUL TEGANAN AC.4.TEGANGAN AC TSB AKAN DI SEARAHKAN OLEH ROTATING DIODE SEHINGGA MENJADI TEGANGAN DC 5.TEGANGAN ITU LALU DIKIRIM KE GENERATOR ROTOR SEBAGAI SUMBER EXITASI,SEHINGGA PADA GENERATOR STATOR AKAN TIMBUL TEGANGAN AC. 6.TEGANGAN ITU SELAIN DISALURKAN KE BEBAN,JUGA DIGUNAKAN SBG SENSING KE AVR,SEHINGGA SAAT TERJADI PENURUNAN TEGANGAN(SAMPAI DI BAWAH SETINGAN KITA),AVR AKAN MENERIMA SENSING DARI GENERATOR STATOR DAN AKAN MENAMBAH ARUS EXSITASI KE EXITER STATOR SHG TEGANGAN YANG AKANDIHASILKAN EXITER ROTOR AKAN BERTAMBAH,SHG TEGANGAN YANG DIHASILKAN GENERATOR STATORPUN BERTAMBAH. BEGITU PULA SEBALIKNYA. 7.UNTUK MENSETING TEGANGAN SESUAI YG KITA INGINKAN,DAPAT MENGGUNAKAN TRIMER YANG ADA DI AVR (YANG BERTULISKAN VOLT)ATAU DAPAT MENGGUNAKAN POTENSIO 10KOHM.CARANYA LEPAS LINK 1-2(PADA TERMINAL AVR) LALU GANTI DENGAN POTENSIO 10K TADI. SEMENTARA ITU DULU YA GAN,KALAU ADA PERTANYAAN SEPUTAR ILMU LISTRIK,SILAHKAN KIRIM EMAIL KE :ilmutentanglistrik@gmail.com.silahkan kirim komentar(yang membangun pastinya)